EC1204BV1.2 functions of operation V02.pdf

(188 KB) Pobierz
EC1204B V1.2 Key Functions of operation
Ver.02
2015.2.23
Time Setting Operation:
Default: year、date 、time、temperature
display rotation
Display
5 sec no Press
not Save
Press'MODE'
Press'PLUS'
Set "Year"
Year Set
10 sec no Press
not Save
Press'MODE'
Press'PLUS'
Set "Month"
Month Set
10 sec no Press
not Save
Press'MODE'
Press'PLUS'
Set "Date"
Date Set
10 sec no Press
not Save
Press'MODE'
Press'PLUS'
Set "Hour"
Hour Set
10 sec no Press
not Save
Press'MODE'
Press'PLUS'
Set "Minute"
Minute Set
Press'MODE'
Save Setting
1/3
Normal Display
1Hz flashing
Functions Setting:
Display
10s no pressed or
long press’MODE’
for 3s
Long Press'MODE' for 3s
Press'PLUS'
Open Hourly Chime
Hourly Chime ON/OFF
10s no pressed or
long press’MODE’
for 3s
Close Hourly Chime
Press'MODE'
Press'PLUS'
Open alarm
Close alarm
Clock Alarm ON/OFF
10s no pressed or
long press’MODE’
for 3s
Alarm H Set
10s no pressed or
long press’MODE’
for 3s
Press'MODE'
Press'PLUS'
Press'MODE'
Press'PLUS'
Set the alarm'mm ' minute
Set the alarm'hh 'hour
Alarm M Set
10s no pressed or
long press’MODE’
for 3s
Press'MODE'
Press'PLUS'
Set ringing time,step/1min
Alarm time Set
10s no pressed or
long press’MODE’
for 3s
Press'MODE'
Press'PLUS'
Close Temperature alarm
Open Temperature alarm
Temperature alarm ON/OFF
10s no pressed or
Press'MODE'
long press’MODE’
for 3s
Press'PLUS'
Set the low temperature
Min Set
10s no pressed or
press’MODE’
Press'MODE'
Press'PLUS'
Set the high temperature
Max Set
2/3
Normal Display
1Hz flashing
Change the LED display:
Press'PLUS'
Display
Press once to change a
display mode LED lights
DS1302 clock circuit is not working properly:
Power on
DS18B20 clock circuit is not working properly:
Power on
Functional specifications:
1、Hourly Chime:
Open Hourly Chime function, 8:00 to 22:00, the buzzer will
ring every hour.
2、Clock Alarm:
open the alarm function , the buzzer will ring at the
specified time, press any button to stop the ringing.
3、Temperature alarm:
Lower than the specified minimum temperature or higher than the
specified maximum temperature, the buzzer will sound and lights
flashing
.
3/3
Normal Display
1Hz flashing